System/Environment setup
Storage configuration details
Internal storage
The DL980 G7 recommended configurations use four internal drives configured with RAID1 for the OS and 11gR2
software. The server supports up to eight internal drives, so additional drives can be added for staging data, logs, or
other requirements.
Table 7. Internal storage controllers
Database Server
Internal Storage Controller
DL980 G7
HP Smart Array P410i/Zero Memory Controller (RAID 1)
HP 146GB 6G SAS 15K rpm SFF Hard Drives
Available upgrades: Battery kit upgrade, 512MB Flash Backed Write Cache (FBWC), 1G Flash Backed
Write Cache, and Smart Array Advanced Pack (SAAP)
External storage
The HP Scalable Warehouse Solution for Oracle reference configuration is based on a model of a core-balanced
architecture which allows for a configuration that is initially balanced and provides predictable performance. This
core balanced architecture is sized for an optimum number of storage components to drive a certain number of CPU
cores. Each CPU core has a maximum throughput of information that can be processed. If we take the per core rate
and multiply times the number of CPU cores, we then have the processing rate for the entire system. To ensure
balanced performance we must ensure that there are minimal bottlenecks in the system that would prevent the CPUs
from reaching their maximum throughput.
It is also possible to increase storage capacity without adding more CPU cores by using larger drives; however
increasing the capacity beyond the optimized configuration will not increase performance. Important to note is that
adding more data but still querying the same sized ranges per query will not decrease performance. Table 8
summarizes the configuration specifics and capabilities of the fibre channel version of the P2000, the P2000 G3
MSA FC.
Table 8. P2000 G3 MSA FC storage configuration details
Model
(12) P2000 G3 MSA FC SSF Array with dual read controllers
Array Configuration
Cache Optimization Standard
Read Ahead Size 2MB
Cache Write Policy write back
Drives
(288) 146GB 6G 15K SFF SAS disks
Drive layout
(288) drives all for user data (24 per enclosure), configured as (48) 6-disk RAID10 vdisks
presented as host LUNs
64KB Chunk size used
(4) 400GB volumes per P2000 array
User Database Space
19 TB
DB Temp Space
500GB
Redo Log Capacity
20GB
Secondary Staging Space (10%)
1.9 TB
Measured I/O Rate
18GB/Sec